RESPIRATOR M900 P3 / WITHOUT INHALATION VALVE
Code.:
ERP:0104092
Product Information
Respirator without inhalation valve with detachable filter for the protection against particles (dusts, fumes and mists).
TECHNICAL DATA
Breathing resistance:
Test flow (l/min) | Inhalation (mbar) | Exhalation (mbar) | ||
Max allowed by the standard | Measured | Max allowed by the standard | Measured | |
95 | 7 | 1.9 | 5 | 1.7 |
160 | 3.0 | 1.4 |
Performance particle filtration – P3:
Filter Type | Class | Flow (l/min) | Aerosol | Max allowed Penetration (%) | Max measured penetration (%) |
P | 3 | 95 | NaCl | 0.05 | 0.001 |
Paraffin oil | 0.05 | 0.001 |
The dust filter media has been tested according to the so called “long duration” tests to EN 143:2000/A1:2006, but the filter is for definition on the reference standard designed to be used for a single shift.
Limitations for use
Do not use in areas where the oxygen concentration is lower than 17 % in volume nor in presence of gases and/or vapours.The filter, for standard definition, is designed for single use only.
CLASSIFICATION
Respirator complying with the provisions of Regulation PPE 2016/425/EU. Respirator provided with FM P3 filter according to EN 1827:1999+A1:2009 standard.