ESCAPE RESPIRATOR H900 ABEK15 / ATEX certified
Code.:
ERP:0104086
Product Information
Escape hood very easy to use that allows escaping from the polluted area in case of fire. The device is provided with filter for organic vapours with boiling point higher than 65°C, inorganic gases and vapours, acid gases, Sulphur Dioxide, Ammonia and its organic derivatives.
The respirator is contained in a practical bag in antistatic fabric with belt loops, ring for wall application and side rings for shoulder use and thanks to its reduced weight and size it can be carried for a complete shift so that it can be rapidly worn in case of accident.
900H is made up of antistatic materials that make it suitable for use in potentially explosive atmospheres, or when the danger of a potential explosion is associated with the presence of gas or dust on the surface (thus excluding mines or deep quarries).
Below are the details of the ATEX marking:
II 1G Ex h IIC T6 Ga -> non-electrical appliances intended for use in the surface industry, where there is the possibility of explosive atmospheres due to the presence of gas – Zone 0
II 1D Ex h IIIC T85 ° C -> non-electrical appliances intended for use in the surface industry, where there is the possibility of explosive atmospheres due to the presence of dust – Zone 20.
Breathing resistance:
Test flow (l/min) | Inhalation (mbar) | Exhalation (mbar) | ||
Max allowed by the standard | Measured | Max allowed by the standard | Measured | |
95 | 8 | 1.8 | 5 | 1.1 |
Gas performance:
Filter Type | Class | Gas Test | Test Concentration (PPM) | Flow Rate (l/min) | RH (%) | Breakthrough concentration (PPM) | Breakthrough time (min) | |
Required | Test | |||||||
A | 15 | C6H12 | 2500 | 30 | 70 | 10 | 15 | 38 |
B | 15 | Cl2 | 2500 | 30 | 70 | 0.5 | 15 | 24 |
H2S | 2500 | 30 | 70 | 10 | 15 | 32 | ||
H2S | 10000 | 30 | 70 | 20 | 5 | 9 | ||
HCN | 2500 | 30 | 70 | 10 | 15 | > 20 | ||
E | 15 | SO2 | 2500 | 30 | 70 | 5 | 15 | 20 |
K | 15 | NH3 | 2500 | 30 | 70 | 25 | 15 | 33 |